Quick Specs
| Category | Security & Control Cable, Shielded, 16AWG, 2 Pair |
| Conductor | 16AWG Tinned Copper Wire |
| Shield | Aluminum Foil, 100% coverage, drain wire |
| Jacket | PVC, Gray |
| Standards | ISO 9001:2008 |
| Certifications | ISO 9001RoHS |
| Packaging | 305m / Box |
Heizka’s 16AWG Shielded Cable 2 Pair is an aluminum-foil-shielded security and control cable built around tinned copper conductors, bundled as two twisted pairs under one shield and jacket so two independent low-voltage control or signal circuits can be run in a single cable. The tinned copper conductors resist oxidation over time for stable long-term contact resistance, while the 100%-coverage aluminum foil shield with drain wire protects both signal paths from electromagnetic interference picked up along conduit and cable tray runs.
This makes it a dependable choice for access control panels, intercom systems, audio distribution, door controllers, proximity readers, keypads, and smoke detector wiring in commercial and residential buildings where two circuits need to share a single run. It ships with a durable gray PVC jacket printed with sequential length markings to reduce installation waste. Every reel is manufactured and tested to an ISO 9001:2008 quality system, is RoHS compliant, and is backed by Heizka’s multi-year warranty for long-term field performance.
Features
- ✓Tinned copper conductors resist oxidation for stable long-term conductivity
- ✓Two twisted pairs (2 Pair) under one shield for two independent control/signal circuits in a single cable
- ✓100%-coverage aluminum foil shield with drain wire for reliable EMI/noise protection
- ✓HDPE insulation for stable electrical performance
- ✓Durable gray PVC jacket for indoor routing
- ✓Sequential length markings printed on jacket to reduce installation waste
- ✓16AWG conductor size for standard-duty security and control wiring
- ✓Rated voltage 300V
- ✓Designed in the USA
- ✓Packaging: 305m/Box
Standard Compliance
- ISO 9001:2008
- RoHS Compliant

Ordering Information
| Item # | Description |
|---|---|
| HEW16S4PC | 16AWG Shielded Cable 2 Pair, Gray, AL-Shield, Twisted, PVC, 305m/Box |
Technical Specifications
Conductor
| Material | Tinned copper wire |
| Construction | 16AWG |
| Maximum conductor resistance (20°C) | 13.7 Ω/Km |
| Capacitance | 100 ± 3 pF/m |
| Capacitance (Conductors + Shield) | 182 ± 3 pF/m |
Insulation & Shield
| Insulation material | HDPE |
| Insulation test voltage AC | 1000V |
| Shield material | Aluminum Foil |
| Shield coverage rate | 100% |
Jacket
| Material | PVC (Gray) |
| Average thickness | 0.6mm |
| Overall cable diameter | 8.6 ± 0.3mm |
| Rated voltage | 300V |
14AWG vs 16AWG vs 18AWG Shielded Cable 2 Pair — Which One Do You Need?
| Feature | 14AWG 2 Pair | 16AWG 2 Pair (this cable) | 18AWG 2 Pair |
|---|---|---|---|
| Item # | HEW14S4PC | HEW16S4PC | HEW18S4PC |
| Max. conductor resistance (20°C) | 8.2 Ω/Km | 13.7 Ω/Km | 21.8 Ω/Km |
| Capacitance | 31 ± 3 pF/ft* | 100 ± 3 pF/m | 98 ± 3 pF/m |
| Capacitance (Cond. + Shield) | 55.9 ± 3 pF/ft* | 182 ± 3 pF/m | 141 ± 3 pF/m |
| Overall jacket diameter | 10.5 ± 0.3mm | 8.6 ± 0.3mm | 6.5 ± 0.3mm |
| Best for | Higher-current control/power runs, longer cable pulls | Standard security and control wiring | Compact, space-constrained conduit runs |
*As printed in Heizka’s catalogue for HEW14S4PC, the 14AWG 2 Pair capacitance figures are given in pF/ft, unlike the pF/m unit used for the other gauges on this page — shown here exactly as sourced, not converted.
Why Two Pairs at 16AWG
A two-pair cable lets one run carry two separate circuits that belong together. Typical pairings are a data pair plus a power pair for a field device, a signal pair plus a return or alarm pair, or two RS-485 / Modbus segments run side by side. Each pair is twisted and the whole cable sits under one aluminium foil shield with a drain wire, so both circuits share the same noise protection along the route.
16AWG is the middle gauge of the range. It has lower resistance than 18AWG for longer runs or for pairs that also feed power, while the cable stays smaller than 14AWG — 8.6 mm overall against 10.5 mm, which is about 58 mm² of cross-section against 87 mm² (calculated from the published diameters).
Loop Resistance and Voltage Drop
The published maximum conductor resistance is 13.7 Ω/km at 20 °C. A circuit uses two conductors, so loop resistance is 2 × run length × 13.7 Ω/km. The table shows what that means for a 4–20 mA current loop at its 20 mA maximum.
| Run length | Loop resistance (calculated) | Voltage drop at 20 mA (calculated) |
|---|---|---|
| 100 m | 2.74 Ω | 0.055 V |
| 300 m | 8.22 Ω | 0.164 V |
| 500 m | 13.70 Ω | 0.274 V |
| 1,000 m | 27.40 Ω | 0.548 V |
Compare the loop resistance with the maximum loop resistance allowed by the transmitter or controller maker. For a pair that also powers a device, multiply the device current by the loop resistance to get the voltage lost in the cable.
Good Practice on Site
- Ground the drain wire at one end only, usually at the controller or panel end, unless the system maker says otherwise. This avoids ground loops through the shield.
- Keep both pairs of one cable on circuits of the same system; do not mix a mains-derived signal with a sensitive analogue pair in the same sheath.
- Cross power cables at right angles where possible, and keep parallel runs apart.
- The 305 m box suits typical floor-by-floor runs; plan cut lengths before pulling to limit waste.
See also the single-pair 16AWG shielded cable, the 14AWG 2-pair and 18AWG 2-pair versions, and the Security & Control Cable range.
Frequently Asked Questions
What is the Heizka 16AWG Shielded Cable 2 Pair used for?
The Heizka 16AWG Shielded Cable 2 Pair is designed for indoor security and control applications, including remote control of security systems, intercom systems, sound/audio systems, door controllers, proximity sensors, key pads, access control, and smoke detectors — wherever two circuits need to share a single cable run.
Why is this cable shielded, and how should the shield be handled?
The 100%-coverage aluminum foil shield with drain wire protects both signal/control circuits from electromagnetic interference. The drain wire should be bonded and grounded at one consistent point — typically the panel end — to avoid ground loops while keeping the shield effective.
What’s the difference between the 14AWG, 16AWG, and 18AWG 2 Pair versions, and which should I choose?
All three share the same tinned-copper conductor, aluminum-foil-shielded, PVC-jacketed, 2-pair construction and differ mainly in conductor gauge. The 14AWG version has the lowest conductor resistance and suits higher-current or longer control/power runs; the 16AWG Shielded Cable 2 Pair is a standard mid-size choice; the 18AWG is the most compact option for tight conduit fill on shorter runs.
Why use a tinned copper conductor instead of bare copper?
Tinning the copper conductor with a thin layer of solder resists oxidation and corrosion over the cable’s service life, helping maintain stable low-resistance connections at terminals in security and control panels.
How is the cable packaged, and what voltage is it rated for?
The cable is rated for 300V and ships in standard 305m boxes with sequential length markings printed on the gray PVC jacket, making it easy to track exact usage during installation.
Every reel of Heizka 16AWG Shielded Cable 2 Pair ships in a standard 305m pull-box with sequential length markings printed along the gray PVC jacket, ready to route two independent control or signal circuits directly into security panels, intercom systems, and access control installations without unnecessary splicing. Only need one signal pair per run? See Heizka’s 16AWG Shielded Cable (1 Pair) for a single-circuit alternative in the same gauge.
Heizka Cable — Designed in the USA, distributed in 20+ countries worldwide.