The Voltrix C2K-Li (Tower) and R2K-Li (Rack 2U) are 2 kVA / 2 kW high-frequency online double-conversion (VFI) UPS systems built on an internal 16-cell LiFePO4 battery pack (51.2 V, 922 Wh). LiFePO4 chemistry delivers up to 3× the backup time of a comparable lead-acid UPS in a lighter, more compact footprint, with a service life exceeding 2,000 charge/discharge cycles. Rated backup > 20 min @ Full Load.
DSP digital control, active input power factor correction (≥ 0.99) and a wide 90 ~ 300 VAC input window make the pair fully compatible with generator sets and unstable grids. Dry contact and MODBUS (RS485) interfaces give direct BMS integration, and the 4-state lithium charger (CC / CV / Floating / Turn-off) can be customised to the battery pack. Both form factors share identical electrical performance — choose Tower for desktop or floor placement, or the 2U Rack model for standard 19-inch cabinets.
Technical Specifications — C2K-Li / R2K-Li — 2 kVA / 2 kW
| AC INPUT | |
|---|---|
| Wiring | L/N + PE |
| Rated Voltage | 208/220/230/240 VAC |
| Voltage Range | 90 ~ 300 VAC |
| Frequency Range | 40 Hz ~ 70 Hz |
| Input Power Factor | ≥ 0.99 |
| AC OUTPUT | |
| Wiring | L/N + PE |
| Output Voltage | 208/220/230/240 VAC |
| Voltage Regulation | ± 1% |
| Output Frequency | 50/60 Hz ±4 Hz (Sync) 50/60 Hz ±0.1 (Free run) |
| Waveform | Pure Sine Wave |
| THDv (Lin. / Non-lin.) | < 2% / < 8% |
| Overload Capability | 100~105%: continuous 105~130%: 60 sec |
| 130~150%: 10 sec >150%: 0.3 sec | |
| EFFICIENCY | |
| Line Mode | 91% |
| Battery Mode | 88% |
| LITHIUM BATTERY & CHARGER | |
| Rated Battery Voltage | 51.2 / 48 VDC (16-cell LiFePO4) |
| Battery Capacity | 922 Wh |
| Backup Time | > 20 min @ Full Load |
| Charging Current | 4A / 8A / 12A / 16A |
| Charging Voltage | 56.8 V (default, 16-cell) Customisable on request |
| Charger Behaviour | CC · CV · Floating · Turn-off (4-state) |
| Protection | 3 over-voltage loop, over-temp / over-pressure interface |
| PHYSICAL | |
| Tower Dim. W×D×H (mm) | 190×415×323 (Std) 190×368×323 (Ext. Bat.) |
| Rack Dim. W×H×D (mm) | 440×500×88 (2U) |
| Tower Net Weight (kg) | 16.5 / 8.6 |
| Rack Net Weight (kg) | 18.5 / 7.7 |
Key Features
- Online double-conversion (VFI) topology — 0 ms transfer, pure sine wave output
- LiFePO4 lithium battery, 16-cell (51.2 V) — more than 2,000 charge/discharge cycles
- Up to 3× backup time vs. a comparable lead-acid UPS, at a fraction of the weight
- Wide input range 90 ~ 300 VAC, 40 Hz ~ 70 Hz — generator compatible, cold start and ECO mode
- Active input power factor correction ≥ 0.99
- Efficiency: line mode 91%, battery mode 88%
- 4-state lithium charger (CC / CV / Floating / Turn-off), charging current 4A / 8A / 12A / 16A
- 50/60 Hz auto-sensing and frequency-converter mode
- RS232 standard; optional USB (1–3 kVA), SNMP / TCP-IP network card for remote monitoring, dry contact for BMS dominant control and MODBUS (RS485) card for BMS integration
Lithium or Lead-Acid at 2 kVA?
The C2K-Li / R2K-Li is the lithium counterpart of the 2 kVA S-Series. It is rated 2 kVA / 2 kW, and its internal LiFePO4 battery is listed at 922 Wh. The table below sets it next to the lead-acid S2K / RS2K using the published data of each model.
| Item | C2K-Li / R2K-Li | S2K / RS2K |
|---|---|---|
| Active power | 2 kW | 1.8 kW |
| Internal battery | 16-cell LiFePO4, 51.2 / 48 VDC, 922 Wh | 4×12V/7AH VRLA (about 336 Wh, calculated) |
| Published backup | > 20 min at full load | ≥ 5 min at 50% load |
| Charging current | 4 / 8 / 12 / 16 A | 1.5 A max |
| Rack net weight | 18.5 kg | 17.5 kg |
The practical difference is energy: the C2K-Li stores about 2.7 times the nominal energy of the S2K in a similar 2U rack format (922 ÷ 336, calculated). As a cross-check, 922 Wh divided by a 2,000 W load gives about 27.7 minutes before losses (calculated), which is consistent with the published figure of more than 20 minutes at full load.
Where It Fits
Choose the C2K-Li where a 2 kW load needs a longer bridge than a standard VRLA battery gives, but without an external battery cabinet: an edge network cabinet in a retail or office building, a CCTV recorder that must keep recording through a typical outage, or a BMS server in a plant room.
Charger and Battery Notes
- Charging current is listed as 4, 8, 12 or 16 A; confirm the value for your order. A higher charging current shortens recharge time between outages.
- The charger uses four stages: constant current, constant voltage, floating and turn-off. The default charging voltage is 56.8 V for the 16-cell pack, customisable on request.
- An external-battery version is listed with lighter weights (tower 8.6 kg, rack 7.7 kg) for projects that need even longer runtime.
Overload and Supply
The listed overload capability is continuous at 100–105%, 60 seconds at 105–130%, and 10 seconds at 130–150%. Full-load input current is roughly 9.7 A at 230 V (2 kW ÷ 91% ÷ 0.99 ÷ 230 V, calculated, excluding charging current); with the charger at its highest setting, allow extra supply capacity.
Dimensions
- Tower: 190 × 415 × 323 mm (standard), 190 × 368 × 323 mm (external battery version).
- Rack: 440 × 500 × 88 mm, 2U. Check that the cabinet depth allows for the 500 mm body plus rear cabling.
Frequently Asked Questions
Is the C2K-Li heavier than lead-acid?
The rack version is 18.5 kg against 17.5 kg for the RS2K, but it carries far more energy.
Compare other lithium models: C1K-Li, C3K-Li, or the full L-Series lithium range.
Ordering Information
| Voltrix Model | Form Factor | Apparent / Active Power | Battery | Part Number |
|---|---|---|---|---|
| C2K-Li | Tower | 2 kVA / 2 kW | 16-cell LiFePO4 (51.2V) | VTX-C2K-Li |
| R2K-Li | Rack 2U | 2 kVA / 2 kW | 16-cell LiFePO4 (51.2V) | VTX-R2K-Li |
Downloads
Certifications & Warranty
Designed and manufactured under ISO 9001:2015. CE (EU Declaration of Conformity), IEC/EN 62040-1 (UPS Safety), IEC/EN 62040-2 (UPS EMC — Class C2), RoHS 2011/65/EU. 2-year UPS system warranty, return-to-base, parts and labour; LiFePO4 battery warranty 2 years or 2,000 full charge-discharge cycles, whichever occurs first. 24/7 technical support with response within 4 hours.
Specifications subject to change without notice. Battery cycle life and backup time are indicative and may vary with operating temperature, load profile and discharge history. Voltrix is a registered brand of Heizka. All trademarks are property of their respective owners.