The Voltrix S6KL (Tower) and RS6KL (Rack 2U) are 6 kVA / 5.4 kW high-frequency online double-conversion (VFI) UPS systems with a long-backup external battery bank (144V/192V). With 0 ms transfer time, input power factor correction of 0.99 at full load and a wide 110~300V (half load) 176~300V (full load) input window, they protect servers, network equipment and control systems against outages, sags, surges and frequency variation.
Both form factors share identical electrical performance; choose Tower for desktop or floor placement, or the 2U Rack model for standard 19-inch cabinets. The external battery module is ordered separately and sized to the autonomy required — runtime is therefore set by the battery bank, not by the UPS. A standard built-in-battery model (S6K / RS6K) is available separately.
Technical Specifications — S6KL / RS6KL — 6 kVA / 5.4 kW
| INPUT | |
|---|---|
| Topology | Online Double Conversion (VFI) |
| Input Config | 1-Phase L/N+PE |
| Nominal Input V | 220 / 230 / 240 VAC |
| Input Voltage Range | 110~300V (half load) 176~300V (full load) |
| Input Freq. Range | 40 ~ 70 Hz |
| Input Power Factor | 0.99 @ Full Load |
| OUTPUT | |
| Output Voltage | 230 VAC (220/240/208V sel.) |
| Volt. Regulation | ± 1% |
| Output Freq (Sync) | 46~54 Hz / 57~63 Hz |
| Output Freq (Bat.) | 50 Hz ±0.05 / 60 Hz ±0.05 |
| THDv (Lin. / Non-lin.) | 2% / 5% |
| Transfer Line↔Bat / Inv↔Bypass | 0 ms / < 4 ms |
| EFFICIENCY | |
| AC → AC (Online) | > 93% |
| ECO Mode | > 95% |
| Battery Mode | > 90% |
| BATTERY & CHARGER | |
| Battery Type | VRLA Maint.-Free Lead Acid |
| Battery Config. | 144V/192V External Battery |
| Float Charge Voltage | 163.8 / 218.4 V |
| Backup @ 50% Load | Per EBM |
| Recharge Time / Max I | Per EBM / 4 A |
| Display / Comm. | LED/LCD / RS232 + USB SNMP (optional) |
| PHYSICAL | |
| Form Factor | Tower / Rack 2U |
| Rack Dim. W×H×D (mm) | 438×88(2U)×500 |
| Net Weight (kg) | 15.4 |
| ENVIRONMENT | |
| Operating Temp. | 0 ~ +40°C |
| Humidity | 5 ~ 97% RH (Non-condensing) |
Key Features
- Online double-conversion (VFI) topology — 0 ms transfer, pure sine wave output
- Input power factor 0.99 at full load — reduces wiring and energy costs
- Wide input range 110~300V (half load) 176~300V (full load), 40 ~ 70 Hz — generator compatible
- Long-backup external battery — max charging current 4 A; runtime set by the external battery module
- AC→AC efficiency > 93%, ECO mode > 95%
- LED/LCD display with RS232 + USB communication, optional SNMP
A 6 kVA UPS for a Full Rack or a Plant Room
The S6KL / RS6KL delivers 5.4 kW from a single-phase supply and runs from an external battery bank. That makes it a fit for a full server or network rack, the central equipment of a CCTV or access control system, or a BMS and fire-alarm interface panel set in a plant room where the required autonomy is longer than an internal battery can give. The rack version is 2U high, which keeps the power stage compact even at this rating.
Battery Bank Planning
The listed external battery voltages are 144 V and 192 V, so a string uses 12 or 16 × 12 V blocks (144 ÷ 12 and 192 ÷ 12, calculated). The listed float charge voltages are 163.8 V and 218.4 V, and the charger supplies up to 4 A.
- Energy: 16 × 12 V × 65 Ah = 12,480 Wh nominal (calculated example, not a Voltrix pack).
- Recharge: at 4 A, a 65 Ah string needs at least about 16 hours to recharge (65 ÷ 4, calculated). For large banks or sites with frequent outages, discuss charger capacity with Heizka at the quote stage.
- Runtime: listed as “Per EBM”; confirm with the battery maker’s discharge table at your real load.
Electrical Planning
- Full-load input current is roughly 25.5 A at 230 V (5.4 kW ÷ 93% ÷ 0.99 ÷ 230 V, calculated, excluding battery charging current). Feed the UPS from a dedicated circuit sized to local code; a plug-in socket connection is usually not suitable at this current.
- Input voltage range is 110~300 V at half load and 176~300 V at full load, which helps on sites with weak or unstable mains.
- AC → AC efficiency is listed above 93% in online mode, above 95% in ECO mode.
Monitoring
RS232 and USB are standard, and an SNMP card is listed as optional. On a networked site, SNMP lets the building or IT monitoring system read UPS status and battery alarms remotely, which matters most for long-backup systems that may run unattended for hours.
Related Models
- S6K / RS6K — 6 kVA with internal battery.
- S10KL / RS10KL — 10 kVA long-backup.
- C6KL-Li / R6KL-Li — 6 kVA long-backup with lithium battery.
Frequently Asked Questions
What rack depth do I need?
The RS6KL measures 438 × 88 × 500 mm. Allow extra depth behind it for the battery and output cables.
144 V or 192 V?
Both are listed. Confirm the string voltage and battery cabinet with Heizka when you request a quote.
Browse the VRLA UPS range.
Ordering Information
| Voltrix Model | Form Factor | Apparent / Active Power | Battery | Part Number |
|---|---|---|---|---|
| S6KL | Tower | 6 kVA / 5.4 kW | Ext. 144V/192V Battery | VTX-S6KL |
| RS6KL | Rack 2U | 6 kVA / 5.4 kW | Ext. 144V/192V Battery | VTX-RS6KL |
Downloads
Certifications & Warranty
Designed and manufactured under ISO 9001:2015. CE (EU Declaration of Conformity), IEC/EN 62040-1 (UPS Safety), IEC/EN 62040-2 (UPS EMC — Class C2), RoHS 2011/65/EU. 2-year UPS system warranty, return-to-base, parts and labour; 1-year VRLA battery warranty. 24/7 technical support with response within 4 hours.
Specifications subject to change without notice. Backup times are indicative and depend on load, temperature, battery age and discharge history. Voltrix is a registered brand of Heizka. All trademarks are property of their respective owners.